Barco Nio 5MP LED (MDNG-5221)

FDA-cleared for radiology and mammography viewing and featuring a number of unique imaging technologies, Nio 5MP LED provides excellent image quality for confident diagnoses.

Thanks to the high-bright LED backlights, Nio 5MP LED helps you see more shades of gray. Additionally, Uniform Luminance Technology ensures subtle details become more noticeable more quickly, resulting in reduced windowing and leveling time. 

Quality assured

The unique front-of-screen sensor guarantees consistent and precise images at all times. It works seamlessly with Barco’s online MediCal QAWeb software for automated Quality Assurance and on-demand calibration, so you are viewing perfect DICOM images. 

High return

Using energy-efficient LED backlights, Nio 5MP LED is as low in power consumption as it is high in brightness. Because it uses less power, the display produces less heat and requires less cooling, which impacts maintenance and operational costs. Additionally, the LED backlights offer a long lifetime – even at high brightness – providing an excellent return on your investment.

Screen technologyDual domain IPS, Normally Black
Active screen size (diagonal)541 mm (21.3″)
Active screen size (H x V)459.8 x 375.3 mm (18.1″ x 14.77″)
Aspect ratio (H:V)5:4
Resolution5 MP (2560 x 2048 pixels)
Pixel pitch0.165 mm
Gray imagingYes
Bit depth10 bit
Viewing angle (H, V)178°
Uniformity correctionULT
Ambient light presetsYes, reading room selection
Front sensorYes
Maximum luminance1020 cd/m²
DICOM calibrated luminance600 cd/m²
Contrast ratio (panel typical)1200:1
Response time ((Tr + Tf)/2) (typical)12.5 ms
Housing colorRAL 9003 / RAL 9004
Video input signalsDVI
DisplayPort
USB ports1x USB 2.0 upstream (endpoint)
3x USB 2.0 downstream
Power rating24 VDC, 4 A; 5 VDC, 0.5 A
Power requirementsThis device shall only be powered by the following medical approved power supply:
Sinpro, type CPU110-201
Ratings marked on the medical power supply:
  • Input rating: 100–240 VAC, 1.5–0.6 A, 47-63 HZ
  • Output rating: 24 VDC, 4.58 A; 5 VDC, 0.5 A
Power consumption43 W (nominal)
< 0.5 W (hibernate)
< 0.5 W (standby)
Dimensions with stand (W x H x D)Portrait: 407 x 523~623 x 235 mm
Landscape: 493.5 x 479~579 x 235 mm
Dimensions w/o stand (W x H x D)407 x 494 x 84 mm
Dimensions packaged (W x H x D)676 x 565 x 317 mm
Net weight with stand13.25 kg
Net weight w/o stand8.25 kg
Net weight packaged19.61 kg (without optional accessories)
Tilt-10° to +30°
Swivel-45° to +45°
Pivot0° to 90°
Height adjustment range100 mm
Mounting standardVESA (100 mm)
Screen protectionProtective, anti-reflective glass cover
Recommended modalitiesAll digital images, including digital mammography
CertificationsFDA 510(K) K133984 for General Radiology
CE1639 (Medical Device Class IIb)
CCC (China), KC (Korea), PSE (Japan), Inmetro (Brazil), BIS (India), EAC (Russia, Kazakhstan, Belarus, Armenia and Kyrgyzstan)

Safety specific:
IEC 60950-1:2005 + A1:2009
EN 60950-1:2006 + A1:2010 + A11:2009 + A12:2011 + A2:2013
IEC 60601-1:2005 + A1:2012
EN 60601-1:2006 + A1:2013 + A12:2014
ANSI/AAMI ES 60601-1:2005 + R1:2012
CAN/CSA C22.2 No. 60601-1:14

EMI specific:
IEC 60601-1-2:2014 (ed4)
EN 60601-1-2:2015 (ed4)
FCC part 15 Class B
ICES-001 Level B
VCCI (Japan)

Environmental:
China Energy Label, EU RoHS, China RoHS, REACH, Canada Health, WEEE, Packaging Directive
Supplied accessoriesUser guide
Documentation disc
Video cable (1 x DisplayPort)
USB 2.0 cable
Mains cables (UK, European (CEBEC/KEMA), USA (UL/CSA; adaptor plug NEMA5-15P), Chinese (CCC))
External power supply
Optional accessoriesGraphics board
QA softwareQAWeb
Warranty5 years, including 45000 hrs backlight warranty
Operating temperature0 °C to 40 °C (15 °C to 30 °C within specs)
Storage temperature-20 °C to 60 °C
Operating humidity8% to 80% (non-condensing)
Storage humidity5% to 85% (non-condensing)
Operating pressure50 kPa minimum
Storage pressure50 to 106 kPa